VACUCLAVE 123S Autoclave

Fast heating phase Short cycle time Perform comprehensive freshwater quality tests Low power consumption because of the different heating system System cleaning automatically Diagnostic systems to evaluate the process and debugging Beautiful and practical design Simple and fast maintenance High capacity of the tank (up to 10 kg using sterile containers)

Hygoclave 50 Autoclave

The Hygoclave 50 is a benchtop, front-loading, automatic dental autoclave manufactured by Dürr Dental. It is a Class B sterilizer with a 17-liter chamber and is designed for efficient and user-friendly sterilization of dental instruments

:Key Specifications

Type: Class B, benchtop, front-loading, automatic autoclave

· Chamber Volume: 17 liters (4.49 gallons)

· Chamber Material: Stainless steel

· Dimensions: 493 x 484 x 642 mm (width x height x depth)

· Weight: 57 kg (empty)

· Supply Voltage: 220 V-60 Hz, 230 V-50/60 Hz, or 240 V-50 Hz

· Maximum Current Consumption (at 230V): 8.9 A

· Maximum Power Consumption (at 230V): 2050 W

· Fresh Water Container: 5.2 liters

· Sterilization Programs: Includes 134°C B Standard, 134°C B Standard Plus, 134°C B Prions, 134°C B Flash, and 121°C B Standard

· Standards: EN 13060, EN 61010-1, EN 61326, EN 61010-2-40

· User Interface: Features a high-resolution 5" touch screen with intuitive, color-coded icons for easy operation

Connectivity: Can be connected to practice networks and documentation software for data logging and monitoring

Safety Features: Includes automatic door locking, integrated water quality testing, and a universal program for complex hollow bodies

:Maximum Load

Unpackaged, bulky load (Type B): 5.5 kg

Packaged, bulky load (Type B): 3.5 kg

Porous load (Type B): 1.5 kg

Packaged, bulky load (B Flash): 0.5 kg

Porous load (B Flash): 0.2 kg

  Hygoclave 50

Hygoclave 50 Plus

Maximum Load for standard Cycles Type B
Unpackaged, bulky load 5,5 kg 6.5 kg
Packaged, bulky load 3.5 kg 4 kg
Porous load 1.5 kg 2 kg
Maximum load for B flash cycle
Packaged, bulky load 0.5 kg 0.7 kg
Porous load 0.2 kg 0.3 kg
Cycle times
134°C B Standard (hold time 5.5 min) 37 38
134°C B Standard Plus (hold time 5.5 min) 38 39
134°C B Prions (hold time 20 min) 49 50
134°C B Flash (hold time 5.5 min) 26 27
121°C B Standard (hold time 20.5 min) 56 56

Vacuklav 23B Autoclave

Printer included 

Device in accordance with the European Directive UNI EN 13060: 2010

Capacity of sterilization chamber 18/23 lt

Two sterilization temperatures: 121 ° C or 134 ° C

Possibility of two programmable "special cycles

3 Universal sterilization cycles type B

3 Test Cycles: 1) Vacuum test 2) Bowie & Dick test / Helix test 3) Spore test

Prion Cycle, Night Cycle

Delayed start of the cycle

Motorized closing of the door

Display for viewing operations with date and time and counting cycles

Vacuum pump drying

Additional drying at the end of the cycle

Parameterization of the operator code

Automatic water loading by the pump

Sterilization Cycle Recording on Integrated SD Card

Fractional vacuum

Possibility of automatic filling via connection with Kiara - Tec water purifier

Predisposition for connection to the printer

Predisposition for connection to the labeler

Possibility of connection to the computera

Hygoclave 90 Autoclave

Technical data

230 V 50 Hz Voltage
47,5 cm × 54 cm × 52 cm Dimensions (H × W × D)
65 kg Weight
19 l Chamber volume
26 cm × 35 cm Internal dimensions, useable volume (∅ × D)
15 – 35 °C Ambient operational temperature
2600 W Maximum power consumption
6 Maximum number of trays
6 kg (10 kg for containers) Maximum load solid
2 kg Maximum load porous
3 Maximum load container 65 mm
<65 dB(A) Noise level*
4,5 l Fresh water and waste water tank volume
93/42/EWG (Klasse IIb), EN 13060:2015, EN 61010-1, EN 61010-2-040, EN 61326-1 Meets the guidelines and standards
* In accordance with EN ISO 1680 Airborne Noise Emissions; measured in a sound-insulated room

Hygoclave 30 Autoclave

 

Hygoclave 30

Sterilization made simple and reliable Sterile instruments and expertise are a prerequisite for successful dental treatment. The Hygoclave 30 Class B Steam Sterilizer, provides the reassurance you need for a sustainably safe practice.

  • Short heating phase thanks to matched choice of material
  • Fast cycle time from 20 min onwards (drying included)
  • Integrated fresh water quality tests
  • Protects the instruments by virtue of little thermal leaps
  • Low power consumption and excellent drying results due to a differentiated heating system
  • Automatic cleaning system
  • Diagnostic system for process evaluation and debugging
  • Elegant and functional design

Lux Seal

Technical Features

POWER SUPPLY: 230 V.a.c. +/- 10% POWER DRAW: 0.7 A POWER FLEX: 2000 mm WITH EEC HOMOLOGATED SOCKET WELD WIDTH: 12 mm WELD LENGTH: 250 mm HEATING ELEMENT POWER SUPPLY: 230 V.a.c. +/- 10% TEMPERATURE MONITORING: SELF-COMPENSATING HEATING ELEMENT WELDING TIME: 5 SECONDS CUTTER: TWO WAY WEIGHT: 9000 g CASING: METAL COATED WITH RAL 9010 POWDER PAINT WELDER DIMENSIONS: WIDTH 470 x DEPTH 360 x H 250 mm PACK DIMENSIONS: 550 x 310 x H 450 mm

Instrument Mini Wash

Surgical instruments washer, specially designed for washing at 65°C all the instruments. Reduces bacterial, accelerates and simplifies the cleaning before sterilization

-Width 575 x depth 490 x H 465 mm

-Net weight: 25 kg

:Data sheet

Company/ ‌‌Brand:Reverberi

Country:Italy

Weight:27 Kg

Unit Size:575 x 490 x 465 mm

Produced Sound:dB(A)55

SERENA B23 Autoclave

Printer included 

Device in accordance with the European Directive UNI EN 13060: 2010-

Capacity of sterilization chamber 18/23 lt-

Two sterilization temperatures: 121 ° C or 134 ° C-

Possibility of two programmable "special cycles"-

3 Universal sterilization cycles type B-

3 Test Cycles: 1) Vacuum test 2) Bowie & Dick test / Helix test 3) Spore test-

Prion Cycle, Night Cycle-

Delayed start of the cycle-

Motorized closing of the door-

Display for viewing operations with date and time and counting cycles-

Vacuum pump drying-

Additional drying at the end of the cycle-

Parameterization of the operator code-

Automatic water loading by the pump-

Sterilization Cycle Recording on Integrated SD Card-

Fractional vacuum-

Possibility of automatic filling via connection with Kiara - Tec water purifier-

Predisposition for connection to the printer-

Predisposition for connection to the labeler-

Possibility of connection to the computer-

SERENA B18 Autoclave

Technical Features

  • Cycles programmables
  • Closing motorized
  • Stainless steel chamber 18-23 lt.
  • New generation software
  • Cycle incubation phial
  • Operator coding
  • Sterilization of instruments extra-long
  • SD card for recording of sterilization data
  • Print labels for envelopes sterilized storage

Device in accordance with the European Directive UNI EN 13060: 2010

Capacity of sterilization chamber 18/23 lt

Two sterilization temperatures: 121 ° C or 134 ° C

Possibility of two programmable "special cycles

3 Universal sterilization cycles type B

3 Test Cycles: 1) Vacuum test 2) Bowie & Dick test / Helix test 3) Spore test

Prion Cycle, Night Cycle

Delayed start of the cycle

Motorized closing of the door

Display for viewing operations with date and time and counting cycles

Vacuum pump drying

Additional drying at the end of the cycle

Parameterization of the operator code

Automatic water loading by the pump

Sterilization Cycle Recording on Integrated SD Card

Fractional vacuum

Possibility of automatic filling via connection with Kiara - Tec water purifier

Predisposition for connection to the printer

Predisposition for connection to the labeler

Possibility of connection to the computer

PRATIKA B20 Autoclave

Able to convert from Type S to Type B sterilizing at the touch of a button, the Siltex Pratika has been designed to combine all the benefits of a Class B sterilizer with the convenience of choice.  It has pre-vacuum and post-vacuum for more efficient sterilizing and drying, fully programmable sterilizing and drying cycles, a Bowie-Dick test cycle, vacuum test cycle and clean and waste water tanks

:Technical specs

Pre-Programmed Cycle Lengths

Unit dimensions: 45 x 39 x 58cm (w x h x d)

Unit weight: 45kg

Chamber capacity: 20 Litre - 24cm diameter, 43cm length

5 litre external dump tank

240V, 10A power outlet required

:Features

Type B or Type S sterilizing

20 litre chamber

121ºC or 134ºC sterilizing cycles

Closed door drying cycle

Digital temperature readout

User selectable cycle lengths

Printer option available

Thermal cut-out safety switches

External waste water dump tank7 litre chamber

inbuilt SD card for electronic backup

SD card reader

Accessories

Sterilizer comes with circular rack system and 4 trays, tray handle, 2 wire racks, dump tank and technical manual. Printers require one additional power point, and connect directly to the sterilizer

PRATIKA B16 Autoclave

PRATIKA are autoclaves designed and built in compliance with the operators' need for functionalit

practical use and safety

Are fully automatic. All functions are electronically servo-assisted, so the operator knows what the

machine is doing at any given moment

Have functional characteristics that make them unique, i.e

AUTOMATIC POWERING, thanks to which the electric heating element maintains the chamber at a

temperature of 80°C for up to 60 min., after which it will automatically switch off if not used, if the

“night” program is selected

Gradual heating to obtain a more accurate temperature and a better sterilizing process

MANUAL WATER FILLING

AUTOMATIC AIR EXHAUST to eliminate the air from inside the chamber at the beginning of

the cycle, thus achieving the utmost steam saturation

DOUBLE SAFETY VALVE to prevent overpressures

DRYING CYCLE included: with thermodynamic system and vacuum pump

SAFETY THERMOSTAT to prevent overtemperatures

Electronic DISPLAY for all functions, with message display and printout

Press-moulded seamless 18/10 STAINLESS STEEL CHAMBER

 POSSIBILITY OF CONNECTING THE DRAIN to the sewage system or can be provided

Vacuklav 41B Autoclave

Quick, easy-to-use and stand-alone – now with DRYtelligence

This high-performance practice steam sterilizer brings the same record operating times as the almost identical Vacuklav 40 B+ Evolution. Its innovative double chamber technology means the sterilization and drying of unwrapped instruments in only 10 minutes; wrapped instruments in a Class-B program require no more than 20 minutes. Both times include fractionated pre-vacuum and drying. The intelligent drying system DRYtelligence uses especially-developed algorithms to adapt the drying to the load in order to shorten the operating times even further and save resources. The Vacuklav 41 B+ Evolution is fitted with an effective air-cooling system, making it into a true stand-alone steam sterilizer as it requires no connections other than to the electricity supply.

After sales phone

00982166804494
00982166804496

Sales Department

00982166912351
00982166912352

Working Hours

Saturday to Wednesday:9Am-17Pm
Thursdays:9Am-14Pm

Fakhrsina

On of the first and largest manufacturers and importers of the highest quality dental equipment in Iran with half a century of experience

All rights are reserved for FakhrSina Company
1403-2024
E-mail : info@fakhrsina.ir